14 (continued)

20 Lack of anti-crack reinforcement in the top at the ends
of slabs affected mode and extent of collapse.

Demonstrates 3-sided slabs and torsional effects
with his hands.

21 'Torsion' an argument for reinforcement.

Partition wall remaining he puts in same category as
the fortuitous teabreak at Aldershot and at the
power station collapse (does he mean Ferrybridge cooling
towers?)

There, but for the grace of God, how many people could
have been killed?

Distribution steel helped.

22 Joints should have been designed to be fixed.

Worried about inconsistencies in arguments heard in
court (at least he'd been there), between 'condition taken'
and 'condition assumed' when considering vital flank wall
inner leaf.

Reinforcement (bars) should go through into the insitu
concrete of joint, bond upwards and back into the top
of the slab (to withstand tension).

23 18 bearing teeth at each end of typical unit.
Outermost 4 underpacked.
(he does not understand purpose of intermittent packing).

But, In time consequences of this system, with effects
of floor heating would cause him greater concern.

24 LAYFIELD. You are not criticizing the underfloor heating?
Bowen - No, not the heating itself -

(But surely the system people must be concerned about WHERE
their work functions and its possible effects. Contrariwise
plenty of talk about the effect of central heating in brick and
stone in 'historic' buildings.)

IMG_0904
419 of 525