24 Layfield: Code of Practice - effective bearing in supporting
(cont) walls should be 3".

Bowen - Yes, but when this Code was written it referred to
block walls, not concrete walls. There should be a minimum
of 3".

Bearings in R.P. (1 1/4") do not secure the normal margin
of safety; were a factor in mode and extent of collapse.

Bonding a very potential danger, a metallic connection sounder.

25 Finish very smooth of sides of units, in fact too good from
point of view of achieving sound inter-bonding with insitu
concrete joint filling. Joint mouth so narrow no margin
for any discrepancies in workmanship.

Workmanship and suspension a factor which should be borne
in mind.

This is a 'system building', not 'industrialized building', which
has been going on for 15 years.

British thinking continental engineers cleverer, but it is
the quality of the workmanship on the site which makes the
strength of the structure.

Engineer needs a correct appreciatio n of what he may
reasonably expect.

No reflection in what men achieve, it is the duty of the
engineer to assess ..

One wouldn't expect same standards in an outpost in Nigeria
as in this country.

(You might get better. Could you get worse? JL)

26 Names 'les responsables', then exonerates.

Imagine amount of jointing done in 4 weeks on 11 floors.

How on earth Ho and others covered every foot of jointing ...

Lists number of skilled men required.

Faster you go more liable you are to make mistakes.
Accidental errors through speed. The Bonus System.

Young engineers today lacking practical experience.