National Tower Blocks Network, Annual Spot Safety Survey

RIVER BANK TOWERS SALFORD 3 MANCHESTER.
REPORT OF INSPECTION CARRIED OUT ON THURSDAY 4th OCTOBER 1990.
Inspection carried out by Graham Doyle Architect.
1.00 INTRODUCTION.
1.01 Riverbank Towers is a 15 storey block of flats built in
the 1960's. It does not appear to be system built. It is
supplied with gas.
1.02 There are six flats per floor with three either side of a
lobby containing two lifts and a single fire escape stair.
1.03 The inspection was carried out by Graham Doyle and Evan
McKenzie the Chair of the Tenants Association. This report was
written by Sam Webb Architect from information supplied.
2.00 MEANS OF ESCAPE AND FIRE SAFETY.
2.01 The block would have been built either under the 1965
Building Regulations or the earlier Metropolitan Byelaws based
on the Model Byelaws of 1953. These would have been enforced by
the Building Inspector.
2.02 Means of Escape is covered by those regulations and would
be dealt with by compliance with BSCP CP3 Chap IV (1962).
This related to blocks of flats and maisonettes over 80'0"
high. The guiding principle of this code and the one which
succeeded it is: "safety of life."
2.03 In a number of important respects Riverbank Towers does
not meet the basic requirements of these regulations.
3.00 THE INSPECTION.
3.01 The inspection started on the top floor in the lobby and
then continued down the fire stairs to the ground floor.
3.01 The inspection took place in the evening. Many lights were
not working. (see chart) There is no emergency lighting.
3.02 The lobbies have centrally pivoted windows 40% of which
obstruct the fire doors. These 6 windows are not locked and
blow open in the wind. The cill is only 1 metre from the floor
and a child could fall out of one of these windows.
3.03 Many flats and the following floors are not numbered &, 8,
9 and 10. In a fire the fire brigade would not know which floor
they were on and they might not find a flat. This could cause
delays and cost lives. It could result in the rescue services
becoming lost inside the building in a fire.