National Tower Blocks Network, Annual Spot Safety Survey

SPORLE COURT WINSTANLEY ROAD WANDSWORTH SW11
REPORT OF SURVEY CARRIED OUT ON FRIDAY 14th SEPTEMBER 1990
Survey carried out by Sam Webb Architect for The National Tower
Blocks Network.
1.00 INTRODUCTION.
1.01 Sporle Court is a 23 storey Tower Block built in the early
1960's.
1.02 Externally the block appears to be of Large Panel
Construction. The block is supplied with gas both for Central
Heating and Cooking.
1.03 The block has two lifts and one internal fire stair. The
accomodation is in the form of Maisonette flats. These are on
two floors and each has an internal staircase.
1.04 Means of Escape from the lower floor is via the main
corridor to the main fire escape staircase. On the upper
bedroom floor escape is via a main corridor to the escape stair
and also via balconies to neighbouring flats.
1.05 The block would have been built under the London Building
Acts 1930-39, and the relevant LCC Constructional Bylaws. The
Means of Escape would have had to comply with BSCP: CP3:
Chapter IV (1962) or its earlier equivalent. I was told that
tenants had lived in the block since 1963.
1.06 The inspection was carried out in the presence of Frances
Clark of The National Tower Blocks Network and Mrs Kakembo a
Tenant living in flat 17. Some photographs were taken.
1.07 While in Mrs Kakembo's flat Ms Clark and I read a number
of documents.
2.00 LARGE PANEL CONSTRUCTION AND GAS.
2.01 Externally this block gives the appearance of Large Panel
Construction.
2.02 In 1968 the use of gas in Large Panel Construction
buildings over 5 storeys was banned by the Government because
the dangers of progressive collapse in the event of an
explosion. The use of bottled gas was also banned.
2.03 The only buildings of this type in which gas could be used
were those under 5 storeys or those capable of withstanding an
explosion of 5psi. If existing buildings could not meet 5psi or
be strengthened to this figure then a lower figure of 2.5 psi
was adopted. In this case gas had to be removed.
2.04 As Sporle Court was built before the partial collapse of
Ronan Point in 1968, did Wandsworth Council ever check to see
if it was safe to continue to use gas in the building in
1968/69? The Government ordered checks in November 1968 after
the publication of the Ronan Point Report.
2.05 In 1969 a Report was prepared on Large Panel Construction
by the then Chief Executive of Wandsworth. This Report was not
presented to the Council.
2.06 As Gas is being used in this block The London Borough of
Wandsworth should confirm the constructional method. Is Sporle
Court capable of withstanding an explosion of 5psi? The
information on construction can be found in the relevant
Housing Committee minutes when the block was built. The Council
records will also show what steps were taken in 1969/70 to
check the safety of this block for the use of gas.
2.07 In 1984 further investigations were carried out into the
construction and site workmanship of Ronan Point. In October
1984 the Minister of Housing and Construction Ian Gow ordered
Local Authorities in England and Wales to carry out Safety
checks on all their system built flats. A number of reports
were written by the BRE about Large Panel Construction. Was
Sporle Court checked as a result of this?
3.00 MEANS OF ESCAPE AND FIRE SAFETY.
3.01 The object of the fire regulations is to prevent the
spread of fire, to contain a fire within the flat of origin, to
prevent the untimely collapse of a building and to allow for
safe, protected Means of Escape.
3.02 Means of Escape would be covered by BSCP CP3: Chap IV
(1962) 'Precaution against Fire'. This assumes that it is no
longer necessary to evacuate a tall residential building (over
80'0") in the event of a fire. The code states: "The guiding
principle in the recommendations which follow is safety of
life. In securing this, means of escape, construction and fire
fighting all play a part."
3.03 In a number of instances during the survey it was found
that Sporle Court did not meet these requirements.