National Tower Blocks Network, Annual Spot Safety Survey

6.00 HIGH WINDS.
6.01 On two occasions during the last three years the southeast
of England has been subjected to hurricane force winds in
October 1987 and Feb 1990. There were also very high winds
during October 1983 in London. Contrary to accepted wisdom such
conditions do not occur once every 300 years. Buildings as high
as Knighthead Point (22 floors) will be frequently exposed to
winds with peak gusts in the order of 105mph. These buildings
stand in the Thames Estuary overlooking Limehouse Reach and
while the building will not blow over parts- particularly
windows are very vunerable in such winds.
6.02 During the hurricane early this year we were told that
some 60 windows were sucked out of the high blocks on the
Quarterdeck. Apart from the risks to occupants of flats where
this happens glass falling from the heights of these blocks
could kill people on the ground.
6.03 This would seem to imply that due regard was not given in
the choice of windows and the forces that they would be likely
to meet during use. Is the glass thick enough? Are the fixings
adequate? In one block of flats in south London brickwork was
removed from upper storeys in the 1990 hurricane.
6.04 These windows would not meet todays regulations with
regard to insulation. They are draughty and while they might be
adequate at ground level they lead to problems in use.
Expensive heat is lost from an overloaded and inadequate warm
air heating system.
7.00 CONCLUSIONS
7.01 Knighthead Point does not meet the requirements of BSCP
CP3 Chap IV (1962) with regard to Means of Escape.
7.02 In the event of a fire tenants could be overcome by smoke
and fumes in the very areas where they would expect to be safe,
ie the fire escape stairs and lobbies.
7.03 This would also affect the rescue services.
7.04 I was told that fire doors had been missing and or broken
for four years (see 3.04).
7.05 There are no instructions to tenants about what to do in
the event of a fire. If this was an hotel these would be
required by law. Notices in English as well as for ethnic
minorities should be clearly displayed throughout the public
areas.
7.06 There is no alternative Means of Escape from each flat. If
this block was designed today this would be a legal
requirement. Therefore it is imperative that the fire escape
areas are made as safe as is humanly possible.
7.07 Smoke alarms and an Emergency Lighting System should be
provided in all the Public Areas inside the block.
7.08 The glazing appears to be incapable of withstanding the
windforces that have occurred during the last three years. In
early 1990 some 60 windows were sucked out of blocks on the
Quarterdeck.
7.09 The heating system is inefficient and may well lead to
tenants using LPG heaters. Some years ago piped gas was removed
from these blocks.
7.10 Events over the last two months have led to higher and
higher oil prices. Past history tells us that they will not go
down even if Iraq does withdraw from Kuwait. Petrol pump prices
have increased by 25% since August 1st 1990 and crude oil has
increased from 19$ a barrel to 40$ in the same time. These
prices will affect all heating fuels, put up the price of
electricity and increase the tenants heating bills to a point
where they either cannot pay them or they resort to 'cheaper'
forms of heating. One result of this could be the use of
extremely dangerous LPG. One simple remedy which would help
would be an overhaul of all the windows in this block and the
other three blocks. Adequate draught stripping should be
provided as a matter of urgency.
7.11 Although this is a long report much of which is critical
the criticisms are made about areas of Knighthead Point where
lives would be at risk in the event of a fire or some aspects
which could lead to dangerous substances being taken into the
block ie LPG because of an inadequate heating system and poor
windows. While these windows may be adequate at ground level
they are not adequate some 200' 0" above the The Thames
Estuary.
7.12 The Concierge system is admirable and it should be
extended to incorporate a 'report back system' so that the
Housing Department can pick up defects. It is a system which
could be incorporated borough wide. The savings through
reductions in damage through vandalism would be considerable.
I am very concerned that fire doors which are crucial to the
safety of tenants and the rescue services in the event of a
fire have remained broken for four years. This is one of the
defects raised by the West Midlands Fire Brigade after the
fatal multi storey fire in Birmingham last July.
Sam Webb Architect for The National Tower Blocks Network
29th September 1990 COPYRIGHT.