National Tower Blocks Network, Annual Spot Safety Survey

ARCHIVE DOCUMENT
Not stated
November 1990

3.04 The flat suffered the usual problems associated with this
form of construction. The tenant mentioned water which leaked
from the upper floor into the bathroom. Cooking smells came
into the flat from other flats. Noise such as people talking in
other flats, we were told, is apparent.

3.05 TWA blocks are prone to gaps in the structure particularly
along the non-loadbearing edges of precast concrete floor slabs
(H1 joint).

3.06 These gaps in the structure deny tenants a one hour fire
separation as required by the regulations (CP3: Chap IV).

3.07 Kedge Point does not meet the basic requirements of BSCP
CP3: Chap IV (1962). The tenancies do not have a one hour fire
separation.

3.08 A number of these flats have been bought by tenants under
the "Right to Buy" terms in the Housing Act.

3.09 The flats contain a considerable amount of asbestos in the
form of panelling.

3.10 The flats have been supplied with new heaters. These have
been installed in such a way as to damage the decorations of
the flats. No attempt has been made at making this damage good.

3.11 We could find no evidence of tenants being warned of the
dangers of the use of LPG in Kedge House.

3.12 This is surprising given that Tower Hamlets has three
other similar Estates containing almost identical Morris Walk
Series buildings: Ocean 1965 3/10 120 flats and Jefferson St
1966 2/10 80 flats and the Barley Mow Estate 1967 3/14 174
flats.

4.00 CONCLUSIONS

4.01 Kedge Point does not meet the requirements of BSCP CP3:
Chap IV (1962) with regard to one hour fire separation of
tenancies. This is surprising given the widespread publicity
over similar deficiencies in TWA buildings from 1984 onwards
including the publication of BRE Reports.

4.02 There are no notices warning of the dangers of the use of
LPG in the block.

4.05 A number of fire doors are broken.

4.04 An entrance porch is under construction presumably for a
Concierge system.

Sam Webb Architect 30th September 1990 COPYRIGHT.

KNIGHTHEAD POINT BARKENTINE ESTATE WEST FERRY ROAD

ISLE OF DOGS LONDON BOROUGH OF TOWER HAMLETS.

REPORT OF INSPECTION CARRIED OUT ON FRIDAY 28th SEPTEMBER 1990

Inspection carried out by Sam Webb Architect

1.00 INTRODUCTION.

1.01 Knighthead Point is a 22 storey tower block built in 1969.
The inspection was carried out in the presence of Frances
Clarke of National Tower Blocks Network and Terese Shanahan of
flat 52 Knighthead Point, The Quarterdeck, Barkentine Estate.

1.02 The Barkentine Estate in West Ferry Road is a 'Mixed
Development'. It consists of a number of different contracts:
Alpha Grove and Malabar St sites (the Quarterdeck) of 4 x 22
storeys total of 348 flats and Alpha Grove Extension, Stuarts
Granolithic Works (Tiller Road) TWA (Larsen - Neilsen) 1/10 40
flats, Kedge House. There are a number of lowrise blocks
including some early 'Orlit' system built houses.

1.03 There are four 22 storey tower blocks of flats on the
Quarterdeck. They were built in 1969. They received approval by
the the GLC Housing Committee in 1965. They do not appear to be
'system built'. They were designed by the LCC/GLC Architects
Department and built by J.M. Hill Contractors.

2.00 CONSTRUCTION AND MEANS OF ESCAPE.

2.01 The regulations governing their construction would have
been The London Building Acts 1930-39 and The London
Constructional Bylaws. As they are over 100'0" they would have
come under Section 20 of the London Building Acts. This is
directly controlled by The District Surveyor.

2.02 They would also have been subject to BRITISH STANDARD CODE
OF PRACTICE CP3: Chap IV (1962) Precaution against Fire. This
governed Means of Escape in Case of Fire and Construction:

"The assumption should no longer be made that buildings must be
evacuated if a fire occurs and high residential buildings should
therefore, be designed so that the occupants of floors above a
dwelling which is on fire may, if they choose, remain safely on
their own floor. It may be necessary to evacuate the floor on
which the fire occurs, and in some circumstances those floors
which are in the immediate vicinity of the fire, but the
occupants of these floors should be free to reach safety in any
part of the building via the staircase."