Skip to main content

Content Warning

Archive material discusses fatal building failures and contains potentially distressing elements.
TBUK15042

National Tower Blocks Network, Annual Spot Safety Survey

ARCHIVE DOCUMENT
Not stated
November 1990

BLOCK "E" BROADMEAD ROAD LONDON BOROUGH OF REDBRIDGE.

REPORT OF INSPECTION CARRIED OUT ON FRIDAY 28th SEPTEMBER 1990.

Inspection carried out by Sam Webb Architect on behalf of
The National Tower Blocks Network.

1.00 INTRODUCTION.

1.01 Broadmead Road Estate Redbridge consists of 6/12 storey
blocks containing a total of 484 flats. They are of Large Panel
Construction and were built by Wates using the Wates System.
They received approval from the Housing Committee in 1966.

1.02 The blocks are named Blocks A-F. An inspection was carried
out in Block "E" with Frances Clarke of The National Tower
Blocks Network. I have reason to believe that the conditions in
Block "E" will be found in all the other five blocks.

2.00 CONSTRUCTION AND MEANS OF ESCAPE.

2.01 The regulations governing the construction of these blocks
would have been The Building Regulations 1965 and Fire
Precautions would have been covered by The British Standard
Code of Practice CP3: Chap IV (1962).

2.02 The introduction to that code states:

"It is, of course, essential that there should be adequate
physical separation between the two occupancies and that the
means of escape from the dwellings should be designed and
constructed so that they can under no circumstances be attacked
by fire or smoke from the other occupancy."

"The guiding principles in the reccommendations which follow
are safety of life."

2.03 These regulations would have been enforced by the London
Borough of Redbridge itself.

3.00 THE INSPECTION.

3.01 We started the inspection on the top floor and walked down
the fire stairs.

3.02 Flats open onto a central internal ventilated lobby and
this in turn opens onto two further lobbies, one containing the
Refuse Chute and the other leads to the Fire Escape Stair. The
ventilation of some of these areas is poor.

3.03 In terms of its original planning Block "E" meets the
requirements of BSCP CP: Chap IV (1962). In practice these are
NOT met and the block is defective in many respects.

TBUK15042
42 of 57