Skip to main content

Content Warning

Archive material discusses fatal building failures and contains potentially distressing elements.
TBUK15037

National Tower Blocks Network, Annual Spot Safety Survey

ARCHIVE DOCUMENT
Not stated
November 1990

SURVEY OF KEDGE HOUSE: FRIDAY 28TH SEPTEMBER 1990

Kedge House is a 10 storey tower block, in the London Borough of Tower
Hamlets. The block contains 40 flats and was built in the Taylor
Woodrow Anglian system (TWA). It formed part of a serial contract
let by the LCC/GLC known as the Morris Walk Series, so named after the
first blocks built at Morris Walk in Greenwich, South London.

Kedge House is 'H' shaped in plan, consisting of two wings of flats with
a central tower containing the escape stairs and lifts. This is linked to
the two wings by prefabricated concrete panels. There are some 1800
flats in a number of similar blocks to Kedge House, in various parts of
London. The TWA system was used on other estates in London, on
Broadwater Farm in Haringey and Freemans Road in Newham. Ronan
Point was part of this contract.

The spotcheck survey of Kedge House revealed a number of fire doors
were broken and some had missing glass. There were no notices
warning of the dangers of the use of bottled gas (LPG) in the block. The
individual flats suffered the usual problems associated with this form
of construction. Water leaking from the upper floor into the bathroom,
cooking smells coming into the flat from other flats and hearing people
talking in other flats, are some of the complaints of tenants. TWA
blocks are prone to gaps in the structure particularly along the
non-loadbearing edges of the precast concrete floor slabs.

These gaps in the structure deny tenants a one hour fire
separation as required by the BSCP CP3: Chap IV (1962). The fire
test carried out in Ronan Point prior to its demolition caused movement
such that the smoke passed around the loadbearing ends of the floor
slabs, allowing smoke and fumes to pass into the flat above.

Ronan Point was demolished following a structural survey and tests
carried out in 1984. As a result of these investigations the Minister for
Housing ordered checks on all TWA buildings in Britain. Was Kedge
House checked?

TBUK15037
37 of 57