National Tower Blocks Network, Annual Spot Safety Survey

ARCHIVE DOCUMENT
Not stated
November 1990

BUILDING REGULATIONS FOR TOWER BLOCKS

The construction of buildings in England and Wales is covered by a
number of different sets of Building Regulations, Acts of Parliament,
the British Standards Codes of Practice (BSCP) and the British
Standards (BS). The regulations referred to in this report pertain to the
construction of tower blocks.

The regulations governing Inner London are made under the London
Buildings Acts 1930-39 and were all enforced by the District
Surveyor. Section 20 of the London Buildings Acts refers to a building
over 100'0" in height or having a large internal volume, which applies to
most tower blocks within Inner London. There was a need for the cut-
off point because fire brigade ladders can only reach a certain height.

Blocks in Inner London also need to comply with one of the following
codes:
BSCP CP3 Chap IV (1962): Fire precautions in flats and maisonettes
above 80' in height. (The 80' refers to the height of a fire brigade
ladder)
BSCP CP3 Chap IV (1971): Fire precautions in flats and maisonettes
above three storeys in height.

The basic requirements of CP3 Chap IV (1962) are that each flat should
be capable of containing a fire for the minimum period of one hour. Any
duct passing through a flat should have a one hour fire stop. The walls
of the duct should also be capable of containing the fire for the same
period. The 1971 code introduced the additional requirement of an
alternative means of escape from each flat or maisonette.

In Outer London, England and Wales tower blocks must comply with one
of these codes depending on when the block was built. Most were built
when the 1962 code was in force, but any subsequent alterations or
improvements to the blocks may need to meet the regulations as defined
in the 1971 code.

In addition to these codes the Building Regulations England and
Wales apply outside Inner London. They first came into force on
February 1st 1966 and were amended in 1972. Before 1966 blocks were
built under a number of Metropolitan Regulations, usually based on
the Model Byelaws of 1953. These would have been enforced by the
Building Inspectors now known as Building Control Officers.

SURVEY OF BLOCK 'E' BROADMEAD ROAD ESTATE:
FRIDAY 28TH SEPTEMBER 1990

Broadmead Road Estate contains six 12 storey blocks, built in the late
1960s, in the London Borough of Redbridge. They are of Large Panel
Construction and were built by Wates using the Wates System. The
blocks are named A-F and the inspection was carried out in Block 'E'.

On each floor the flats open onto a central internal ventilated lobby and
this in turn opens onto two further lobbies, one containing the refuse
chute and the other leading to the fire escape stairs. In the original
planning Block 'E' met the requirements of BSCP CP: Chap IV (1962)
however in practice, in the event of a fire, the safety of tenants would
be seriously compromised because of the following defects:

A considerable number of fire doors are defective, including broken
glass, not closing properly or no handles. A safe exit in an emergency
would also be hampered by broken refuse chute covers which were left
lying in the lobby. There is no emergency lighting in this block. These
defects do not appear to be recent.

In the event of a fire the fire stair and escape lobbies could become
seriously smoke logged. This could cause loss of life and make fighting
the fire more difficult. There is no alternative means of escape from
each flat. If this block was designed today this would be a legal
requirement. Therefore it is imperative that the fire escape areas are
made as safe as is possible.

There are no instructions to tenants about what to do in a fire. If this
was a hotel these would be required by law. Notices in English as well
as other community languages should be clearly displayed throughout
the public areas of all these blocks. It is also recommended that
emergency lighting be fitted in all lobbies and the fire stair. Smoke
alarms should also be fitted in these areas.