TBUK15038

National Tower Blocks Network, Annual Spot Safety Survey

ARCHIVE DOCUMENT
Not stated
November 1990

SURVEY OF SPORLE COURT: FRIDAY 14TH SEPTEMBER 1990

Sporle Court is a 23 storey tower block built in the early 1960s, in the
London Borough of Wandsworth. The block is divided up into
maisonettes, which are on two floors, there being an internal staircase.
The block has two lifts and one internal fire stair.

Externally it appears to be of Large Panel Construction and supplied
with gas for both central heating and cooking. Following the collapse of
Ronan Point in May 1968 the use of gas in Large Panel Construction
buildings over five storeys was banned by the Government because of
the dangers of progressive collapse in the event of an explosion. The
use of bottled gas was also banned.

The Government ordered checks to be carried out on all Large Panel
Construction blocks in November 1968 following the partial collapse of
Ronan Point in May 1968. As Sporle Court was built before 1968, did
Wandsworth Council ever check to see if it was safe to continue to use
gas in the building, as ordered by the Government? In 1984 as a result
of further investigations into the safety of Ronan Point the then
Minister of Housing and Construction, Ian Gow, ordered local authorities
in England and Wales to carry out safety checks on all their system built
flats. Was Sporle Court checked as a result of this?

The flats in Sporle Court have a piped gas supply. In the event of a leak
in the supply pipe there is no way for the gas to escape except into the
corridor. The survey revealed a large number of vents that were
damaged or loose. Gas supplies should not be situated in an unvented
duct.

Several more questions arise in relation to Sporle Court as gas is being
used in this block. The London Borough of Wandsworth should confirm
the constructional method of Sporle Court. Is Sporle Court capable of
withstanding an explosion of 5psi (as relevant legislation demands)?
This information is available in the relevant Housing Committee
minutes when the block was built. The Council records will also show
what steps were taken in 1969/70 to check the safety of this block for
the use of gas.

The means of escape from the maisonette flats in Sporle Court whilst
on the lower floor is via the main corridor to the main fire escape
staircase. On the upper bedroom floor escape is via a main corridor to
the escape stair and also via the balconies to neighbouring flats. Means
of Escape legislation assumes that it is no longer necessary to evacuate
a tower block in the event of a fire. But this requires adequate fire
prevention and protection within the block. The survey of Sporle Court
found that is did not meet these requirements.

During the survey of Sporle Court a number of fire doors were found to
be inoperative. The use of timber panelling on the ground floor is
questionable. It could pose a serious threat to the safety of the
occupants by filling the escape stair with smoke and fumes if it caught
fire. The amount of rubbish that had been allowed to accumulate in the
block cause another serious fire risk.

These are a few examples of the many found in Sporle Court. The
conclusions following the survey are that Sporle Court does not appear
to meet the basic requirements in regard to means of escape. It also
appears to be of Large Panel Construction with a gas supply. No
evidence of strengthening could be found. This poses a serious question:
Is Sporle Court safe in the event of a gas explosion or will it suffer
progressive collapse?