TBUK1009
Diagram, H14, Mortlake Road

HAND-DRAWN diagrams
Title: Not stated
Location: Mortlake Rd
Company: Taylor Woodrow-Anglian Ltd.
[OCR Text from diagram/document]
Figured dimensions only are to be taken from this drawing
DRY PACK TO COLUMN BASE
LEVEL
SLAB ON BEAM
SEE SECTION
BASE PLATE
GROUTING
G.L.
REINFORCEMENT BARS
BENT INTO POSITION
FOR 2ND AND 3RD LIFTS
GROUT BEDDED
LEVEL
Taylor Woodrow-Anglian Ltd.
MORTLAKE RD
H14
FIG. B3
TBUK1009
9 of 63