TBUK1010

Diagram, H.14 Joint, Mortlake Road

ARCHIVE DOCUMENT
Start of document

HAND-DRAWN diagrams
Title: PLATE & ANCHOR JOINT DETAIL AT END BAY CROSSWALLS
Location: Not stated
Company: PHILLIPS CONSULTANTS LTD.

Text in diagram:
* 3 1/4"
* 3/4" DIA PHILLIPS STUD ANCHOR 7" LONG.
* APPLIES AT 17TH TO 22ND FLR. INCL.
* 9" x 6" x 3/4" MS PLATE.
* CERTITE PACKING.
* STRUCT. TOPPING (SEE SPEC) STRUCT. TOPPING MAY BE REDUCED 1/8" TO SUIT FLOOR COVERING. 1" COVER.
* HEAVY DUTY WASHER.
* MESH B.S. No C.385 OR B.S. No 108.
* 1" DIA VENT
* 3/4" DIA. BLACK BOLT TREATED.
* 1" INT. DIA. "SAFTY PIN" BEND ON 8mm DIA ROD.
* 2:1 SAND/CEMENT EXPANDING GROUT PRESSURE FED INTO CORES WHERE STUD ANCHORS OR BOLTS OCCUR
* 4" x 4" x 5/16" CONTINUOUS ANGLE.
* 2 3/4"
* 7 3/8"
* POLYSTYRENE BUNGS
* 3/4" DIA. PHILLIPS STUD ANCHOR 4 3/4" LONG
* 3 1/2"
* 3" x 2" WELDED LUG. (SEE M4/10)
* 2 1/4"
* APPLIES AT ALL CEILINGS EXCL. ROOF
* 6" x 4" x 3/8" CONTINUOUS ANGLE.
* 6 3/4"
* 3/4" DIA. MS BLACK BOLT TREATED

Other text:
DRAWING IN ACCORDANCE WITH M.H.L.G. CIRCULARS 62/68 & 71/68
R.F. STAINARD M.I.STRUCT.E
P.P. SIR FREDERICK SNOW & PARTNERS CONSULTING ENGINEERS
CONTRACT DRWG.
REVISIONS:
LUGS TO L. HAND ANGLE OMITTED & BOLT POSITION IN SLAB AMEND'D 26.1.70 JW B.
VENT HOLE & NOTES ADDED 14.1.70 JW A.
DATE 30/10/69
DRAWN BY J.W.
CHKD BY H.D.
SCALE 1/4 F.S.
DRAWING TITLE: NEWHAM STRENGTHENING
DRAWING No. NS/MC/16.B.
PHILLIPS CONSULTANTS LTD. CONSULTING ENGINEERS
WESTERN HOUSE, WESTERN AVENUE, EALING, W.5.
BRANCH OFFICES AT BRIGHTON & NEWCASTLE-UPON-TYNE
CLEVER ROAD
FIG. 82
REF 18/2 mason 01119