TBUK1008
Diagram

HAND-DRAWN diagrams
Title: ELEVATION SHOWING TYPICAL PANEL REINFORCEMENT.
Location: Not stated
Company: Not stated
OCR Text:
MESH (A).
MESH (B)
2N° 1/2" DIA. H.T. BARS IN INNER SKIN (OUTSIDE FACE).
2N° 1/2" DIA. H.T. BARS IN INNER SKIN (OUTSIDE FACE).
MESH (B)
3N° 1/4" DIA. S.STEEL BARS FROM INNER TO OUTER SKIN.
3N° 1/4" DIA. S.STEEL BARS FROM INNER TO OUTER SKIN.
MESH (C)
ONLY 2N° 1/4" DIA. S.STEEL BARS PROVIDED IN 9'-0" LONG PANELS.
8 N° 1/8" DIA. S.STEEL BARS BENT AROUND MESH REINFORCEMENT IN INNER AND OUTER SKINS.
VARIES 17'-6" TO 9'-0"
1" COVER TO MESH.
MESH (B)
MESH (A)
MESH (A).
MESH (B)
1/2" DIA. BARS.
1/4" DIA. BARS.
MESH (B)
MESH (C)
MESH (C)
1" COVER TO MESH.
2 1/8" COVER TO MESH.
9'-8"
ELEVATION SHOWING TYPICAL PANEL REINFORCEMENT.
L6698 / Sk. 101.
TBUK1008
8 of 63