Bison or Bull?

Now its down to the underwear
Mr. Terry Dicks of the London Borough of Hillingdon Council estimated a bill
of £1 billion to cover repairs to Bison nationally, "Sometimes its a factory
fault sometimes an erection fault". Bison Director John Peacock refused to
comment on the estimate, his colleage Brian Bagnall also refused to comment,
but added "that the Bison System housing was safer than many traditional
methods of building"
Internal & External Water Penetration:
Quote " Drypack insulation was either saturated to such an extent that it was
completely useless, or it was missing altogether ". (Manchester)
Quote " It appears drypack insulation was completely missed out of the building
specification in some blocks ". (Sedgefield)
Quote " In various positions it was possible to examine the drypack(Dry Mortar
filling) although it was of reasonably good quality, it was not always continious
as might be expected ". (Nottingham)
Quote " There are small areas of insulation deficiency, which produce problems
disproportionate to the size of the deficiency ". (Hillingdon)
Quote " Many baffles to prevent water penetration are missing, damaged or have
slipped, also many horizontal joints between panels are suspect because of damage
misalignment or un-satisfactory workmanship. (Manchester)
Quote " Water penetration through joints and cracks is having an adverse effect
upon concrete in general, the process is a vicious circle. (Sedgefield)
Heating Ventilation And Thermal Insulation:
Quote " It is obvious that inspection of the form ofheating and its intensity,
that the thermal insulation to the structural shell is inadequate"(Sedgefield)
Quote " Heating and ventilation are not adequate or in balance as was found
recently in a pilot improvement study ". (Manchester)
Quote " There have been numerous complaints about the heating system being
inadequate, high electricity bills etc., this is only part of the problem"
(Sedgefield)
Quote " Higher thermal insulation standards would have reduced the exceptional
heat losses, there-by reducing the costs to tenants". (Sedgefield)
Quote "Heating is not supplied to bedrooms, it is advisable that additional
ducts be fitted to remedy the situation, however the overiding consideration
is to the adequacy of the system" (Sedgefield)