Skip to main content

Content Warning

Archive material discusses fatal building failures and contains potentially distressing elements.
IMG_0982

Notes on Inquiry

ARCHIVE DOCUMENT
Not stated
1 August 1968

40 Advantages of system building must not be lost.
LN at RP not designed against progressive collapse.
Perhaps no definite decision yet as to whether R.P. can
be made safe.
It may not have been a gas explosion!
Gas requires a LEAK
cocker taps off
careasing was sound.
Could only have come from NUT joining flexible connector
to back of cooker, fitted originally by Gas Board.
41 Search in records for this fitting.
Nut faulty.
Steps being taken to see if there are any other weak nuts
or whether this a lone rogue.
41,42 700,000 flexible connectors with nuts sold.
200,000 hexagonal nuts to be returned/issued to date.
500,000 octagonal nuts.
42 Gas Board fitters (6,000 [illegible] visits a day).
Instructed to report if they find a hexagonal one,
and it will be changed.
Miss Hodge's nut - the automatic lathe, OR WHATEVER IT
MAY BE, unfortunately coughed when it was turning out
Miss Hodge's nut.
One got an excessive chamfer on it!
PROBABLY not on any other!
43 Difficulties in the way of concluding that it WAS a gas
explosion.
1 The mechanics of obtaining a leak at all.
2 . The mechanics of forming an explosive mixture
in the flat, without prior detection.
The nut was not fractured before. Smedley IX p.35.
Pike left a gas-tight joint. IX p.41.
Nut would have to be broken for leak at this point. IX p. 47.

IMG_0982
497 of 525