IMG_0902

Notes on Inquiry

ARCHIVE DOCUMENT
Not stated
Unknown

14 (continued)

9(cont) 1939-46 Port of Bristol Authority, Avonmouth Docks.
1946-47 Engineer in Chief, Brabazon Aircraft Assembly
Hall? One and on, a page of qualifications including the
Shell building - buildings up to 400 ft. He was
appointed by Gas Council.

10 He has been reading the evidence.

Code of Practice III 'issued '62, written some time
earlier.

Review of this code?

It was not intended to be applied in full to walls
of this kind.

Institution considers new Codes a matter of urgency.

(No!)

Shortage of fractural test data on walls of this type.

24 lbs/sq.ft. is basic pressure on which R.P. was based.

11 24 lbs/sq.ft. is NOT an uptodate figure, based on an
outofdate code 1952.

Fire regulations. Bedroom doors do just comply.
Store cupboard: he questions the practice; it is a source
of fire.

12 Identification of walls (flat 90) on his drawing.

13 Building 'an open-sided egg-crate'.
Strength of corners and joints of prime importance.
Extremely susceptible to collapse if no monolithic
action attained.

external flank walls; treated as
some parallel internal vertical diaphragms
for lateral cross walls in 1 direction; of re or semi
wind forces 2 core walls in opposite inforced concrete
direction;

floors complete horizontal
diaphragms linking them

IMG_0902
417 of 525