A 276 Miss V Andrew - My father told me that
chackney[illegible] not about 3 o'clock
John Barrow a survivor told about it.

B 277
Duncan W Roe Comdr RN retd 85 Andover Rd Chelt Glouc
air raid shelter move 1" DPC prov.

C 287/1. RP LR Cram. Ref paper 287 and ? on
form of same from Mr Bullegh dated
15 July comments which are as follows.

Q 3 (ii) (a)
2 Following the more detailed studies which
have since been made I would not now
'feel safe' in living in the end and corner
rooms of la TW building even if gas
were prohibited.

Q 3 (ii) (b)
3 I would feel safe in living in the inner
sections of a TW bldg or in any other ind
building in which the joints are tied units
to resist prog coll.

Q 3 (iii)
4 The ends gen & corners in partic of
this bldg are weak in their resistance to
p coll:
5 Resis to p c can be intro by tying floors
to the walls. From gen observation and
limited testing, it has been demonstrated
that this tying in can only be effectively
achieved by units jointing.

6 All types of panel construction make
some effort to tie walls and flos tog
from observation the TW building
is weakest in this respect.

Q 3 (iv)
7 It seems essential 'to ban' the
use of the TW 'friction tied' form
of constn in the end & corner
wings.
8 This ban seems much less essential
for the 'inner' sections of the bldg.