Eric M Wright 19 Patrick Road Plaistow E.13 28 5 68
Very int [illegible] re foundations etc.
Mr A Crump 66 Beckit Av E Ham E 6 27. 5.68
V g photos.
Mtg 28.5.68 Cuary / Charlton Humphries Roberts T.Sol.
He (Mr Cuary) mentioned that small bricks with bonding
with bonding between would have had a quater
instance to explosion than the walls at Ronan Pt.
Mr Cuary was told that we had heard from
a fairly reliable source that TW had been dismissing
men for not putting on the fish plate. Mr Cuary
suggested that the fish plate should be counted in
the debris though he though it would be an
unlikely occur coincidence if the 18th floor did
not in fact have a fish plate.
H4/758/3 Plan Cover 7.
Page 122.
Cuary DCS Memo 5-68.
snd end 1 2 3 4
5 In the LW system as used at Canning Town the
following unsatisfactory details were found and
should be avoided or improved in current
work.
continuity between Vert and Horiz Panels.
6 The B bet LW and HF Panels is prov by
a min steel plate which is attached at one
end to a vertical dowel rod connecting the
upper and lower Wall panels. the tie is anchored
to the floor panel at the other end by a
smooth steel ferrule there are 2 such ties every
in a panel width of about 10'0"
7 In collapse the smooth ferrule pins
were pulled from the concrete panel
and the steel tie plate was badly
distorted. Prefer the connection should
be prov by with prov as reinf grouted
between the members. As a second
pref, the tie plate should be plenty
more frequent in number and more
positively anchored.