WESA_12_1_01p12

148.
Draft 5.8.68.
20 8 68 First draft to Min.
23 8 68
p 4 6 Result
110/111 As a result when we had a portion of such
a joint opened up it was fnd some of the mortar
on the outer edge of the packing was look. In these same
joints the use of the two longit bars shown in
Fig - was not spec on the dwgs and as a result
witnesses dif somewhat as to the levels at which
these bars were actually placed.
115 Fortunately added!
p 9. Then must have ma. Mem F E N to express
That Roman Point can
grave doubts withstand the wind loads that
are likely to come upon it during its lifetime
see 135.
100 mph - 60 lb/ft^2.
SIR ALFRED PUGSLEY,
these loading act are much in excess for
those which RP was des and prob would lead to
some of the upper flank wall panels being
we have
found simil. forced away and to compression stresses at
the defect to the base of the main load - bearing walls suf
4.Mar to start crushing and splitting of the conc panels
1984
in Dodson and joints there. It might be argued
that to allow for an extreme wind likely
to occur only once in 60 yrs is too
cautious yet such action is effectively
to allow only for an estimated certainty,
However in pop terms to make walls strong
enough to resist 60 lb st is only to make
them about as strong as the glass in a
good window.
these results which we agree are indict
by the avail evidence mean that the flank
wall panels of RP partic near top of bldg
should in the course of improving the
structures pos around them to be made
to withstand safety wind gusts of the order 60 psf.
As re major matter of failure of the
bldg as a whole we think that
wind tunnel mrs should be conducted
as soon as poss on a model of RP