Skip to main content

Content Warning

Archive material discusses fatal building failures and contains potentially distressing elements.
TBUK2221

National Tower Blocks Directory 1992

ARCHIVE DOCUMENT
Not stated
1992

continued from previous page
So far the campaign by the tenants in
Belfast has succeeded in persuading the
Housing Executive to:
[ ] issue a new leaflet on fire safety in
high-rise blocks;
[ ] appoint a fire safety consultant and

carry out checks on all high- and medium-
rise blocks;
[ ] agree to carry out fire safety work on
Moveen House and Divis.

William Pollock speaks for the
determination of the tenants when he says:

“We will continue to keep the pressure
hose of publicity fully turned on the
Executive”.

CONTACT
Tenants’ Lobby Group, c/o William
Pollock, 103c Shaw Road, Belfast, BT11
9PS.

EXTERNAL FIRE PROTECTION :
A CHECKLIST

There are huge benefits to be
obtained for tenants from
externally insulating and
overcladding high-rise blocks.

These include the elimination
of condensation and rain
penetration, the reduction of
energy consump-tion
(creating cheaper heating for
tenants), and the revitalisation
of the blocks’ external
appearance.

However, as a result of
experience gained from
previous fires in high-rise
buildings, new codes and
standards have been
established to ensure
protection and eliminate fire
spread (see Knowsley
Heights example).

We provide here a general
guide to best practice and the
legal requirements, and in
particular the new building
regulations which came into
force after June, 1992.

GOOD PRACTICE
CHECKLIST

1 Use masonry cladding or
concrete on the ground floor.

2 Use street furniture or bollards
to remove risk of rubbish storage
against the building.

3 Prov de disposal areas for
large items of household waste,
remote from the building.

4 Extend the duties of site
managers/caretakers to
regularly inspect the interior and
exterior of the building, and to
arrange for any dumped rubbish
to be removed immediately.

5 Fire protect any bin stores
adjacent to the building.

6 Ensure that any overcladding
systems to be used are well
proven and have been
independently tested (i) for
materials of construction (ii) for
any fire barriers to be used, and
(iii) that the system will still
function properly with fire
barriers installed, particularly
the ventilation of the cavity.

BUILDING REGULATION
REQUIREMENTS FOR
BUILDINGS OVER 15
METRES HIGH

1 Cladding material to be
class “0” front and rear face.

2 Non-combustible insulation
to be used.

3 Fire barriers to be inserted
horizontally at every floor level.

4 Fire barriers to be inserted
vertically corresponding to the
external walls of each flat unit.

(Information from Capex, an
overcladding company
who have redesigned their
system following the fire in
overcladding, provided by
them, at Knowsley Heights
on Merseyside).

138
NTBN DIRECTORY

TBUK2221
221 of 248