Skip to main content

Content Warning

Archive material discusses fatal building failures and contains potentially distressing elements.
TBUK1016

Diagram, Joint Detail at Flank Walls, Clever Road

ARCHIVE DOCUMENT
Start of document

HAND-DRAWN diagrams
Title: JOINT DETAIL AT FLANK WALLS
Location: CLEVER ROAD
Company: P.P. SIR FREDERICK SNOW & PARTNERS / PHILLIPS CONSULTANTS LTD.

Text from diagram:
3'-0"
M.I. STRUCTURE
P.P. SIR FREDERICK SNOW & PARTNERS
CONSULTING ENGINEERS
3/4" DIA. HILTI ANCHOR OR SIMILAR APPROVED.
9"x4"x1/2" ANGLE CLEATS
APPLIES AT
ALL FLRS EXCL ROOF SLB
Screed may be reduced by 1/8" to suit floor covering.
3:1 SAND/CEMENT MORTAR PACK
MESH B.S.C385 OR B.S. 108
1" COVER
2:1 SAND CEMENT EXPANDING GROUT GRAVITY FED WHERE FIXING OCCURS.
1" DIA. VENT
STRUCT. TOPPING (SEE SPECIFICATION)
3/4" M.S. BLACK BOLT TREATED (SEE SPEC.)
1" INT. DIA. "SAFETY-PIN" BEND
28 m/m DIA M.S. ROD
2'-0" EACH LEG
MINERAL WOOL BUNG IN POLYTHENE BAG.
CONTRACT DRWG.
4"x4"x 5/16 CONTINUOUS ANGLE
3/4" DIA. HILTI ANCHOR OR SIMILAR APPROVED.
APPLIES AT
ALL CEILINGS EXCL ROOF SLABS
NOTES ADDED 14.1.70 JW B
Note added Re Screed etc 8/1/70 YZK A
DATE 23/9/69
DRAWN BY N.O.
CHKD BY A.D.
SCALE 1/4 F.S.
DRAWING TITLE: NEWHAM STRENGTHENING
DRAWING No. NS/MC/12
PHILLIPS CONSULTANTS LTD. CONSULTING ENGINEERS
WESTERN HOUSE, WESTERN AVENUE, EALING, W.5.
BRANCH OFFICES AT BRIGHTON & NEWCASTLE-UPON-TYNE.
FIG B2.
REF. 18/2 mason D5519

End of document
TBUK1016
16 of 63