Diagram, Joint Detail at Flank Walls, Clever Road

HAND-DRAWN diagrams
Title: JOINT DETAIL AT FLANK WALLS
Location: CLEVER ROAD
Company: P.P. SIR FREDERICK SNOW & PARTNERS / PHILLIPS CONSULTANTS LTD.
Text from diagram:
3'-0"
M.I. STRUCTURE
P.P. SIR FREDERICK SNOW & PARTNERS
CONSULTING ENGINEERS
3/4" DIA. HILTI ANCHOR OR SIMILAR APPROVED.
9"x4"x1/2" ANGLE CLEATS
APPLIES AT
ALL FLRS EXCL ROOF SLB
Screed may be reduced by 1/8" to suit floor covering.
3:1 SAND/CEMENT MORTAR PACK
MESH B.S.C385 OR B.S. 108
1" COVER
2:1 SAND CEMENT EXPANDING GROUT GRAVITY FED WHERE FIXING OCCURS.
1" DIA. VENT
STRUCT. TOPPING (SEE SPECIFICATION)
3/4" M.S. BLACK BOLT TREATED (SEE SPEC.)
1" INT. DIA. "SAFETY-PIN" BEND
28 m/m DIA M.S. ROD
2'-0" EACH LEG
MINERAL WOOL BUNG IN POLYTHENE BAG.
CONTRACT DRWG.
4"x4"x 5/16 CONTINUOUS ANGLE
3/4" DIA. HILTI ANCHOR OR SIMILAR APPROVED.
APPLIES AT
ALL CEILINGS EXCL ROOF SLABS
NOTES ADDED 14.1.70 JW B
Note added Re Screed etc 8/1/70 YZK A
DATE 23/9/69
DRAWN BY N.O.
CHKD BY A.D.
SCALE 1/4 F.S.
DRAWING TITLE: NEWHAM STRENGTHENING
DRAWING No. NS/MC/12
PHILLIPS CONSULTANTS LTD. CONSULTING ENGINEERS
WESTERN HOUSE, WESTERN AVENUE, EALING, W.5.
BRANCH OFFICES AT BRIGHTON & NEWCASTLE-UPON-TYNE.
FIG B2.
REF. 18/2 mason D5519