TBUK1015

Diagram, Clever Road, Joint Detail at Corridor Wall

ARCHIVE DOCUMENT
Start of document

HAND-DRAWN diagrams
Title: JOINT DETAIL AT CORRIDOR WALL / FIG. B2
Location: Not stated
Company: PHILLIPS CONSULTANTS LTD. / SIR FREDERICK SNOW & PARTNERS

TEXT EXTRACTED FROM DIAGRAM:
- 9" x 3/4" M.S. PLATE
- 3/4" DIA. M.S. BLACK BOLT TREATED (SEE SPEC.)
- 3" x 4" x 1/2" ANGLE CLEAT APPLIES AT 17 TO 22 FLR. INCL.
- STRUC. TOPPING (SEE SPECIFICATION)
- GRANO FINISH
- 3/4" DIA. ANCHOR BOLT
- CORRIDOR SLAB
- 3/4" DIA. ANCHOR BOLT
- 4" x 4" x 5/16" ANGLES APPLIES AT ALL CEILINGS INCL ROOF
- 3/4" DIA. M.S. BLACK BOLT TREATED (SEE SPEC)
- DRAWING IN ACCORDANCE WITH M.H.L.G. CIRCULARS 62/68 & 71/68
- R. F. STANNARD M.I.STRUCT.E
- P.P. SIR FREDERICK SNOW & PARTNERS CONSULTING ENGINEERS
- CONTRACT DRWG
- NOTES ADDED 14.1.70 JW B
- General Amendments 31/3/70 YRK A
- DATE 23/3/70 DRAWN BY N.O. CHKD BY A.F. SCALE 1/4 F.S.
- NEWHAM STRENGTHENING
- DRAWING No. NS/MC/13.B
- PHILLIPS CONSULTANTS LTD. CONSULTING ENGINEERS
- WESTERN HOUSE, WESTERN AVENUE, EALING, W.5.
- BRANCH OFFICES AT BRIGHTON & NEWCASTLE-UPON-TYNE.

End of document
TBUK1015
15 of 63