Sam Webb, Letter regarding Roystonhill, Glasgow

Fairhurst went on to say that in his opinion the blocks could not
be strengthened to withstand the sort of wind loadings expected in
the lifetime of these buildings.
*** These flats do not attain a desirable standard of
structural efficiency and it is likely that their effective
life will be less than that of a normal insitu reinforced
concrete or steel frame building. In these circumstances
strengthening measures against wind loading would only
provide a partial remedy against defects, and possible high
maintenace costs.
Last week I visited Glasgow. I am very concerned about the
Roystonhill Flats. It is my considered opinion that the pressed
metal overcladding which is fixed to timber battens and which has
a Polyurethane foam backing is a serious fire risk and would
endanger the lives of all the inhabitants of the block if it
caught alight.
There would be no way that the fire brigade could fight such a
fire in an unstopped void 25 stories high. You will no doubt
remember the terrible fire at the Summerland Leisure Centre in the
Isle of Man in 1973. This was caused by a fire in a void behind
pressed metal cladding. I have doubts that this cladding at
Roystonhill conforms to the Scottish Building Regulations in
relation to fire, fixed as it is to the outside of these buildings
and I wonder what testing was carried out before it was fixed? You
are no doubt aware that the regulations were changed in relation
to external walls and fire risk as a result of the Summerland
disaster in which 50 people died.
This overcladding has another serious fire hazard and that is the
effect of the intense heat that would be generated if the
Polyurethane caught fire and its effect on the structure of the
building. On 18th July 1984 at my request the London Borough of
Newham held a fire test in Ronan Point. This fire as you may
remember had to be put out after only 11 minutes because of the
danger of collapse of the building. As a result the Consultant
Engineers reccommended to Newham that the bottom 8 floors of 5
tower blocks similar to Ronan Point be evacuated on fire safety
grounds. This was later endorsed by the BRE. This can be confirmed
if you contact Councillor Fred Jones the Leader of Newham Council.
It is my opinion that the overcladding has produced a serious
health risk to the tenants. The humidity in these flats is the
worst that I have ever come across. I have no doubt that the
internal conditions caused by this overcladding are and will
continue to produce severe respiritory disorders. From discussions
that I had it would appear that many children in these blocks
suffer higher than average illnesses. This cannot be entirely
unconnected with the high humidity found in these flats. If the
children are found to have had lower than average triple vaccine
then the reason may well lie in the fact that they have so many
colds and so cannot be given their jabs.
If formally asked to give an opinion on conditions on the flats by
the tenants I would say that the humid conditions within these
flats constitute a health risk and are a Statutory Nuisance under
the Public Health Acts. It would also be my considered opinion
that the metal overcladding constitutes a Statutory Nuisance and
puts the lives of the tenants at unnecessarily at risk in the
event of a fire.