Skip to main content

Content Warning

Archive material discusses fatal building failures and contains potentially distressing elements.
WESA_5_3_09p1

Letter from Sam Webb to John Clay of London Borough of Greenwich

ARCHIVE DOCUMENT
18 November 1984
Start of document

                                                            November 18 1984

John Clay
The Housing Department
The London Borough of Greenwich
Peggy Middleton House
Woolwich
London S.E.18

Dear John,

                              Morris Walk Estate Greenwich

Thank you for the second set of documents which arrived safely.

Following the meeting at your office on 31 October 1984 I have been looking into ways in which I can advise the tenants.

The question of finding suitable engineers to carry out the work is proving a difficult one.  As I have found in the past on schemes in other parts of the country, engineers who have been called in to look at ailing system built schemes often have a history of involvement in the design of a similar system or have carried out repair work in the past.

It could be argued that some firms in the past have given less than impartial advice to Councils.  Perhaps at the back of the minds of these firms is the thought that if they come down too hard on system x they may be later held liable for possible faults in system y which they themselves designed.  All of the I.D. precast cast concrete systems used for housing are similar as are all the post 1969 repairs.  Apart from one or two details the principles are almost exactly the same.  I have found identical defects on blocks in Leeds built in V.D.G. system and Ronan Point in T.W.A.

The real problem of these buildings is structural and concerns stability.  The question any Council must ask itself is: "Is it worth spending anything from £25,000 to £75,000 per flat to bring that flat up to a habitable and safe level if no one will guarantee the work for the next forty years?"

To give value for money it is not unreasonable to assume that the work must last that length of time.  Forty years is the remaining term of the outstanding loan.  Indeed I would be surprised if the original contract documents between the London County Council and Taylor Woodrow Anglian did not state in some form or another that the buildings had to last for at least sixty years from say 1964/5 until 2024/5.

I have read most of the documents that you gave me.  They are extremely interesting but if I were a councillor or a tenant with little or no technical knowledge I would find them daunting to say the least.  Some of the documents require translation.

[continued]

As I mentioned to you when we met, an argument that is frequently voiced about structures is:

          "The strength of the building has proved adequate for all
          loading conditions experienced since construction."

If the building is standing up that indeed is self evident.  However the question that should be asked is:

          "Will the strength and stability of the building prove
          adequate for all loading conditions that will be experienced
          in the future?"

If the answer to that question is less than certain then there is a risk.

It is often argued that designing for explosions is not part of the aim of an engineer designing a block of flats or indeed any structure.  The designers of Ronan Point argued this at the Inquiry.  However it is something that is in fact taken into account by various codes of structure or structural principles even though they do not state it directly.

Traditional construction in brick using principles laid down by the Babylonians is very strong and can absorb enormous and unexpected loads.  For instance, did John Whicheord the Architect of the Grand Hotel in Brighton consider that 120 years after his creation a 20 lb. bomb would be exploded in a (sixth floor bathroom?  If the cabinet had been in a hotel built using loadbearing panels then I have little doubt that they would all have been killed and most if not all of the building would have fallen down.

There is enormous resilience in traditional construction be it loadbearing brick, steel or concrete frame.  Such structures can absorb enormous forces before failure.  They have very high inbuilt factors of safety.  Apart from the Grand Hotel, the GPO tower is a case in point and many buildings in Northern Ireland which have had bombs exploded in them, sometimes repeatedly.

If an L.P.G. heater fueled by calor gas or propane were to explode in a Morris Walk series flat then there would be a disaster.  (See my article in 'Building 18 May 1978 concerning Hunslet Grange Leeds).  The removal of such heaters should be treated as a matter of urgency by all concerned whatever the long or short term proposals for the flatsare.  I fully appreciate the difficulties involved in doing this, the problems involved in providing alternative fuels etc. but I cannot stress the dangers too highly.

Liquified Petroleum Gas can cause explosions in two ways.  Firstly, through a leak.  It is heavier than air and there have been explosions in boats through this.  The second and possible more serious risk is if there were a fire in a flat which had one or more L.P.G. heaters in it.  If such an accident occurred the public outcry would be enormous for the following reasons.

The installation of L.P.G. into a building  is governed by the Building Regulations only when the appliance is fixed to the building, or if it is a gas cooker, refrigerator etc.  In these installations the cylinder and the connections to enable the cylinder to be changed must be outside the building and must be in the open air.  Even where caravans have L.P.G. cylinders these are always on the tow bar in the open air.

[continued]

From a manufacturers point of view if the cylinder is put in a metal case which is then put on wheels, it is no longer a fixed appliance within the meaning of the Building Regulations.  Putting it on wheels however does not remove the risk - see The Guardian p.11 9 Nov. 1969 "Ronan Point : Judgement in Doubt" by Terence Bendixson.  As fuel prices rise, as tenants become unable or unwilling to pay for electricity then they will resort to fuels which they see as being under their control.  They can turn the heating on and off at will, something that people living in a house take for granted.  Not unreasonably they will use L.P.G. heaters, because they do not understand the dangers.  L.P.G. cylinders contain 32 lb. of gas, the suitcase at the Grand Hotel had 20 lb. of explosive, the explosion at Ronan Point was caused by only a few pounds of town gas, if indeed that really was the cause.  (Para. 91: Ronan Point Report 1968.)

The problems of an L.P.G. explosion apply to the lowrise (Area B) as well as the highrise blocks (Area A).

You have asked me if I would consider producing a Report for the Tenants which can be used as a checklist.  I would be pleased to do this.

One of the first things such a report should do is demonstrate by means of diagrams etc. how the blocks are built.  Morris Walk is only one of ten estates throughout London.  As they were built the details of the structures changed.  It would appear that buildings on the earlier estates are not as stable as the later ones.

The report would cover a number of headings:

1.  The history of Larsen & Nielsen/Taylor Woodrow Anglian.
2.  Danish Practice - Danish Codes etc.
3.  Ronan Point.
4.  The implications of the Public Inquiry Recommendations.
5.  The bolted angles and the dual standards of 2.5 p.s.i. and 5 p.s.i.  Statements made at various times by the GLC, the Minister of Housing, Newham, District Surveyors etc.
6.  Explanatory 3D drawings of joints showing how the structure works and how it was put together.
7.  How the structure changed from Estate to Estate.  According to my records there are ten Morris Walk series Estates containing 36 tall blocks of flats based on the 'H' shaped plan.  These were handed over to the GLC by TWA between April 1965 and Jan. 1970.
8.  An assessment of the problems likely to arise or be found at Morris Walk Woolwich.  This would include drawings.
9.  How these problems could be rectified or not as the case may be.
10.  Conclusions and Recommendations.

[continued]

You asked me if I would have any problems working with B.D.P.

As I said on the phone I would have none at all.  Last Thursday, 15 November '84 I supplied B.D.P. (Mr. Feneron) with a complete list of the Morris Walk series Estates.

You asked me to state a consultancy fee for this work.  I have come to the conclusion that the best solution is to charge on an hourly rate of £40 an hour and a maximum time of 100 hours.  I would produce copies of my report for the tenants and for the council.  I hope this meets with your agreement and I look forward to hearing from you.


Yours sincerely,


Sam Webb RIBA

End of document
WESA_5_3_09p1
11 of 70