55 If vapour, what and where from?

First a vapour explosion? Second, gas?

Some witnesses reporting 2 explosions, some, one.

Majority of his experts accept the ONE EXPLOSION evidence.

56 40 to 90 cubic feet of gas may have accumulated in flat.

Extent of leak through the faulty nut? 10-25 cubic feet
per hour.

Tests still being carried on.

Sir A. Pugsley questions Moore.

An estimate of time scale of explosion build-up?

57 Moore hesitates, then hazards '100 miliseconds for wave
to cross a 10'0" space'. Steep part - 10 miliseconds.

Detailed analysis of rise of pressures in flat.

58,59 Suggests wall panels should not be so strong that indue
force is built up within a building.

Sir A. Pugley says this is what they meant by venting.

Griffiths questions, 'clears his mind', about methane,
(ruled out) aerosol, nature of a dust explosion.

59 Moore explains 'saw dust, coal dust explosions.

Wide distribution of dust dangerous.

Easier to come about in a LONG CORRIDOR, OR INSIDE A DUCT,
e.g. A VENTILATION DUCT.

60 Improbable in Flat 90 but looked into.

(No-one seems to remember the conditions in those flats JL)

A liquid explosion?

Why no smell? Moore - Sir, I do not know.

With liquid type Miss Hodge would have stirred it in moving
across flat.

We do not know whether Miss H did or did not smell gas
from evidence.

(She was ASKED, and said 'not a trace' - JL)

IMG_0912
427 of 525