Notes on Inquiry

55 If vapour, what and where from?
First a vapour explosion? Second, gas?
Some witnesses reporting 2 explosions, some, one.
Majority of his experts accept the ONE EXPLOSION evidence.
56 40 to 90 cubic feet of gas may have accumulated in flat.
Extent of leak through the faulty nut? 10-25 cubic feet
per hour.
Tests still being carried on.
Sir A. Pugsley questions Moore.
An estimate of time scale of explosion build-up?
57 Moore hesitates, then hazards '100 miliseconds for wave
to cross a 10'0" space'. Steep part - 10 miliseconds.
Detailed analysis of rise of pressures in flat.
58,59 Suggests wall panels should not be so strong that indue
force is built up within a building.
Sir A. Pugley says this is what they meant by venting.
Griffiths questions, 'clears his mind', about methane,
(ruled out) aerosol, nature of a dust explosion.
59 Moore explains 'saw dust, coal dust explosions.
Wide distribution of dust dangerous.
Easier to come about in a LONG CORRIDOR, OR INSIDE A DUCT,
e.g. A VENTILATION DUCT.
60 Improbable in Flat 90 but looked into.
(No-one seems to remember the conditions in those flats JL)
A liquid explosion?
Why no smell? Moore - Sir, I do not know.
With liquid type Miss Hodge would have stirred it in moving
across flat.
We do not know whether Miss H did or did not smell gas
from evidence.
(She was ASKED, and said 'not a trace' - JL)