Notes on Inquiry

ARCHIVE DOCUMENT
Not stated
19 July 1968

12 (continued)

56, B.L.C. explains and demonstrates what he thinks is wrong with
57, structure, at length, but clearly and simply. He has been to
58 site 7 times.

59 May questions ?

BLC mentions new Bedford County Hall, "as you have probably heard
that is a building 700' long." Views opposite to TWA's man.
RAH on expansion and contraction of concrete. BLC says cracks
will open and concrete and rubbish enter them, so they will not
go back again.

Worried about lack of restraint on floor slabs and wall; it
doesn't move, breathe, expand with floor. It is liable to
pull off in some places.

His firm have inspected the rubble, to investigate binding
between insitu and factory concrete.

BLC very pointed about collapse. "We went up into flats, the
parts that had not fallen, 200 ft., to have a look at this."
(The truth, which sound very sharp in THIS courtroom - JL)

"Bonding very expensive."

May: "What did you find as to the bond at R.P.?"
BLC: "Virtually none. NEARLY ALL CAME AWAY FROM THE PARENT
PRECAST CONCRETE UNITS."

Loading.

60 "With due respect to Dr. Chapman and tests (loading) he is
carrying out, we do not think they simulate conditions on
site" + elaborates on why, clamps in lab, joints in perfect
condition, perfectly grouted, etc.

Tests - today it give up to 900 lbs. Amazing HOW R.P. collapsed.
It was certainly not subjected to 900 lbs.

61 May: "Dry mortar packing?"
BLC: "So soft my brother could break it with his hands."

Enquiry on failure of a prestressed concrete bridge found it was
caused by bad packing of dry mortar. Most difficult as its a
long stretch to push in. Difficult to get anything like 5,700.

62 FLAT LY CONTRADICTS R.A.H. Quite possible to turn this typeof
structure into a very very rigid eggbox or egg crate with proper
re-inforcement, so that even flats above could not collapse.

Floor panels very big which makes it evenmore important to have
right jointing. There is good recorded information on Spanish
Civil War where shells had gone clean through a block of flats,
without their falling down (in situ type flats)