Notes on Inquiry

10 (continued)
16 The sight of the wreck (photographs). (One can still see
actual thing as it was - JL) VW - "In some cases a slab has
purely, directly, sheared at its end." GOODFELLOW having
suggested that 'teeth' held.
17 Description of 'progressive collapse'.
18 Term 'ferrule' used by Dr. BATE. Watson says is hollow,
circular, tubular part of the insert into which 5/8 bolt is
inserted.
In some cases 'bolt' is not as tight as it could have been.
19 GOODFELLOW "£5/sq.ft. industrialized building figure given."
wrong, he corrects himself. "More of the order of 5/-,
although TW would be delighted if the figure was in fact £5
not 5/-".
20 Joint (V 3) corner of flank wall, where it turns back into
corridor, parted in flat 90 and flat above and flat below.
21 Analysis of joints and behaviour of floors and walls in
structure. Major factor in disaster a load falling on floor 5.
22 Speculations as to what may or may not hold in a collapse.
25 "Gilley Law", Sunderland highest till R.P. 16 storeys.
Independent wind calculations done for R.P. (L.N. originally
designed this sytem for 6 floors).
27 "Joints not tested to 'ultimate'". VW.
28 At Imperial College they are being tested at this moment.
"Is it the intention to go on till final failure?"
(Must be like the rack. But who is paying? Would like to be
at interview between TWA and their accountants. JL)
Strength of joint about 600 lbs/sq.ft.
30 GOODFELLOW'S cunning, V EVELEIGH. "With respect, not quite
right, to keep on equating district surveyor with the customer.
Customer was GLC.
(But how long can he keep flogging this 'shifting the
responsibility' gag? JL)
Eveleigh obviously referring to HALL's (Wandsworth) intervention
re: strap. 2 or 3 days before results of fracture test will be
known. After their lunch.