Joan Littlewood, Notes

ARCHIVE DOCUMENT
Not stated
Unknown
Start of document

Torque applied in increments of 10lb units
nut fractured
A - no chamfer - 150lb ft
B 45° " 160 lb ft
C " 95 lb ft
D " 80 lb ft
E " 52 lb ft

With vaseline
Ball load to fracture nut 1.43 tons similar to C D E -

Overtightening?
Overtightening ± axial pull?
} No facts on which to base a judgment

P.20 Smiley
Nut broke because of an axial load.

Ball Fracture commenced from sharp fillet
P.39. machined inside the nut between internal thread & flange
FRACTURE CAUSED BY MAKING CONNECTION DURING ORIGINAL INSTALLATION
OR R.P. ...
POSTULATES ORIGINAL INSTALLATION.
TORQUE REQUIRED TO CONTINUE FRACTURE TO COMPLETION AT R.P. RELATIVELY SMALL
P.23 Pite took IT TO COMPLETE FRACTURE

WHAT BROKE NUT ???
IF IT WAS HANGING TOGETHER AT RP WHAT SEPARATED IT ??
The strength of the nut may not have been reduced by damage

Stempipe handed by Police to Yallops - Dr. Yallop & Dr. Moore P.28. thence to Smiley.
Easing in torque P.35
Shear failure or creep?
Ball - ?
I.W must have let him in early.
to see gas cooker?

End of document