Notes

"These ~~investigations have led Messrs. Flint and Neill~~
to ~~express~~ grave doubts as to the ability of the
structure to withstand the wind loads that are likely
to come upon it during its lifetime.
These loading actions are much in excess for those
which Ronan Point was designed and probably lead to
some of the upper flank wall panels being sucked away
and to compression stresses at the base of the main
load bearing walls sufficient to start crushing and
splitting of the concrete panels and joints there.
It might be argued that to allow for an extreme wind
likely to occur only once in 60 years is too cautious.
Yet such action is effectively to allow only for an
estimated certainty. However in popular terms to
make walls strong enough to withstand 60 lb per square
foot is only to make them about as strong as the glass
in a good window."
Ronan Point the world's tallest non continuous large panel
structure was only designed for a 63 m.p.h. wind (24 lb
per square foot), what the newspapers would have made of
Pugsley's last comment and whether subsequent events would
have proved different is now purely a matter for speculation.
On 1 October the retyped version of the much mutilated third
draft went to the Minister of Housing, Anthony Greenwood.
It did not contain Pugsley's last comment on wind written
in biro down the left hand margin of the previous draft,
"However it would seem to me very unfortunate if in
a wind liable to break many glass windows (those at
Ronan Point have been found by test to break at 16 lb
per square foot) the inhabitants of Ronan Point should
have to worry also about the structural stability."
House
In his Commons statement and subsequent press conference on
6 November 1968 Mr. Greenwood forecast,
"that the risk of progressive collapse from high wind
loading would be found to be insignificant compared
with the risk of explosion."