WESA_12_2_02p4

Sam Webb, 'Joan Littlewood and the Riddle of Ronan Point'

ARCHIVE DOCUMENT
Not stated
Unknown

so too cautious is effectively to allow only for
an estimation certainty, However in popular
terms to make walls strong enough to withstand
60 lb square foot is only to make them as strong
as the glass in a good window, " SIC.
Pugsley's epitaph reads as follows,
" However it would seem that the to me
very unfortunate if in a wind able to
break many glass windows (those at Ronan
pt have been found by test to break at 16 lb psf)
the inhabitants of Ronan Point should have
to worry also about the structural stability."
The much mutilated third draft went to
Greenwood on 1 Oct 1968 in his subsequent
press conference on 6 Nov 1968 he forcast,
" that the risk of progressive collapse from
high wind loading would be found to be
insignificant compared with the risk of explosion.
Of course it can now be argued that
the buildings have been strengthened, but have
they adequately for there are nearly 600 up
and down Britain. According to the Report the
explosion was between 3 and 12 psi yet only
the loadbearing walls have been strengthened
to 2 1/2 psi, by unprotected steel,
" The chances of an fire explosion occurring
after a fire, at a point in time when the
heat had had time to lower the yield
point of the steel to such an extent that
it could no longer take sufficient tension
(there is a factor of safety of four), is so
remote that the Council (GLC) decided
that fire protection of the steel angles
was an unnecessary expense " Sir Hubert
Bennet Architect to GLC. 9 July 1970.
There is of course no steel work strengthening
to the non load bearing panels which could
be blown out only with catastrophic effect with
a pressure of 1 1/4 lb psi!
In a letter to Arthur Lewis MP dated 30 April
1970 the Minister had the following to say
" In so far as Mr Webb is saying there is a
loophole in the Building Regulations, I am always