WESA_12_1_01p55

WESA_12_1_01p55

ARCHIVE DOCUMENT
Not stated
16 August 1968

horiz w ext wall shall be due to wind safely.
a horiz press equal to a static press of at least
30 lb sq ft are to act uniformly over the area
of one panel from either side."

B
An opinion concerning the perf of the skins
of the TB under high wind 4.15.

Clinal Strength
With due regard to the poor variation
of strength of the conc within the precast
wall panels and in mortar jts and of the
inf of imperfections on wall planarity, &
alignment and of the interaction between
floors and walls we are of the op that
the highest median comp stress should
not exceed 50% of the spec cube strength
if safety and sev of struc is to be
insured.
In ext flank walls subject to
greater eccentricity of loading from
floors and diff movements in the
bedding joints a safe limit is the peak
median stress might be of the order
of 35% of the spec conc cube strength
or of the crushing strength of the
bedding mortar.

C Pug 16.8.68 - Marlow. Pugsley to Marlow
2. I am still awaiting a res call from
Warren - in part those ref to in
transcript D 18 p 68 at B & C p 70 at A
and p 71 at A please urge them.

1
(1) Thank you for your recent batch of
papers will you please be sure that
all future one are addressed above and not to
univ. I have just seen [illegible] newspaper*
a rep of the results of BRS test on
[illegible] - much more relevant than any
such fige we have so far had.
Please send me copy of that report
as soon as poss.

3. I have arr to visit F & N this
afternoon you can get me there by
phone after 2 30 if you need. I prop
to go the thru 'routine' calcs
and then discuss some spec ones

* WHY WASN'T HE THERE?

WESA_12_1_01p55
55 of 57