9, St Anne's Close,
Highgate West Hill,
London. N.6.

26/8/68

Dear Sir,

Ronan Point in Perspective

The following points are facts-

1. Part of a twenty storey building collapsed on May 16th killing five people. All National Press.

2. A serious gas explosion at Mare Street Hackney injured many people and severely damaged a store. This frame building did not fall down (Times Aug 21 page 2).

3. On 6th August a French newspaper 'France Ouest' published a report about a large prefabricated wall panel building which collapsed after a gas explosion, 139 people were made homeless, and the City of Versailles is opening a case against a Mr. X. The building is in Rue Jean-Moulin Yvelines France, and the cause might be an attempted suicide by gas.

4. Two independant engineers at the inquiry produced evidence in the form of calculations to the fact that the joints used at Ronan Point would fail at a uniform pressure of 2 lbs. a square inch (TWO). This was disputed in cross examination.

5. On Wednesday 14th August, the Building Research Station carried out an experiment on the joints. A test rig was set up and pressure was applied to walls and floors by hydraulic rams. The joints failed at 1.8 lbs. per square inch (one point eight) which is equivalent to an explosion of two pints of petrol in a room. If the pressure had been applied to the ceiling as well, the failure rate would have been even lower. (Manchester Edition of Daily Telegraph, 16th August, page 1, entitled "Why the joints failed").

6. The design calculation for these panels was that the joints would withstand a stress of 4000 lbs. sq. ft. before failure. (Daily Telegraph 16.8.68).

7. On Wednesday 24th July, an Architect while giving evidence at the Inquiry said that all similar buildings in the country should be inspected, and he warned of the dangers of "do it yourself" handymen. He was not cross examined at all on any of his evidence.

8. The Times, 10th August, carries a middle page report of a visit by a reporter to the Clever Road Site. People were moving in to an adjacent block to Ronan Point and on the 18th floor a tenant is reported as making a hole through a wall, and apologises to the reporter for the 'mountain of rubble' on the floor'

9. Thursday 15th August 'Ministry Acts' All Newspapers.
We all know from experience how slowly Ministries act why then did the letters to Local Authorties go out immediately?, Why was the

[pencil scribbles in bottom right corner, illegible]

1.

gas turned off at once?, Why were all the blocks to be speedily reappraised?, and the public told to leave the worrying to us?, (MOLHG).

10. We are told that all gas is to be turned off and electricity will be used, in practice, electricity will not be used because it is too expensive, any Housing Manager will tell you of the complaints he receives about excessive electricity bills. The tenants will, almost without exception resort to paraffin and store 5 gallon drums to top up heaters. As well as the serious risk of fire the consequences of item 5 are extremely grave.
The under floor heating must cause expansion and contraction of the floors thereby weakening the joints. The gas explosion at Ronan Point caused the building to collapse and yet the tenant was not killed, or made deaf by the pressure caused by the explosion (through perforated ear drums).

11. On science of these systems where the wall panels go right to the ground, children can and do, pull out the weather strips between the panels. Once this is done they cannot be replaced, and a whole storey height joint at the bottom is subject to rain penetration. Once water gets inside it cannot get out and this can happen in a tower block.

12. Lastly and by far the most serious is that there are no building regulations governing this type of construction, and also something which you yourself quote "...... sponsors may occasionally have modified structural details themselves or have been asked to do so by clients."

In your Editorial you say that it is comforting to demand universal prescience from designers to whom we entrust our lives. Of course it is , the 1963 R.I.B.A. Contract implies just that. When the final certificate is signed the architect is in effect giving warranty for the entire buildingand its structural stability.
The London Building Acts, Building Regulations, District Surveyors etc., take utmost pains to ensure that buildings do not fall down, and kill or infirm people. You imply that the public should ' grin and bear it' because they get run over. Well, if I get killed in a car crash that is my concern, but if I design a building which falls down then can I really claim I was only experimenting, and say sorry because I killed someones grandfather.

The MOHLG have now issued details of remedial measures to be carried out (I refer you to page 316 A.J. 21st August perhaps you will reprint thses drawings).

1. The wall panel as drawn cannot be cast in concrete, if it is cast in a battery the top part cannot be vibrated, that is why in the present system the tops are flat. If it is cast face down it is impossible to cast the top and bottom of the panel.

2. The top feather edge will break off in transit. How does the continuous rod feed in at the edge of the building?, These rods will have to be in short lengths in order to be threaded through the hoops, This will reduce the amount of concrete in the joint.

2.

4. All walls and floors will now have to be propped and shuttered, slabs and walls will no longer be pre-finished inside because of grout runs and damage. Shuttering will have to be struck in the normal way observing the normal curing periods. This will slow down progress and turn an industrialised system back into a traditional system.

5. The joint between the pre-cast and insitu concrete is at the point of maximum shear stress. If the joint fails the floor panel will fall. If the joint was the other way round it would form a wedge and stay in position.

6. The fixing bolt which is left out from your drawing, and upon which so much accuracy depends is now placed in the insitu concrete. How are they to be held in position while the concrete is vibrated and while it sets, and what happens if one is omitted either by a genuine mistake or sheer carelessness. Does the contractor cut a hole and grout one in ?

7. By rigidly fixing the wall panels at the top only and not at the bottom, the remedies are not achieving a continuous structure.

It would appear that either the measures have not been fully worked out or that the MOHLG is now seriously worried about these buildings and that the remedial measures are now so onerous and will prove so expensive in practice that builders will resort to a frame or insitu reinforced concrete for this form of package deal. This might be good diplomacy for future blocks but what of the people still living in the existing ones ? At best they will get an inspection and work will be done to the joints. The impossibility of doing this properly and thoroughly supervising and inspecting the work in progress will be apparent to anyone who has run a building contract.

If Ronan Point was a "one off" building it would, without doubt, be demolished as unsafe. If there were two such blocks on the same site they would be pulled down for the same reasons. I find it questionable, therefore, that because there are many such similar blocks throughout the country, they should be allowed to stay. If we accept the spirit of your leader we are in fact gambling with peoples lives and must accept the possibility of another disaster which this time could kill a hundred people. People expect their homes to be "as safe as houses". Why doesn't the A.J. ?

Yours faithfully,

N.P. Dip.Arch.(Hons)