TBUK5001

Letter from London Fire Brigade, 'Tall Buildings - External Fire Spread'

ARCHIVE DOCUMENT
London
London
May 2017
Start of document


Dear Sir/Madam,

TALL BUILDINGS – EXTERNAL FIRE SPREAD

The fire at Shepherd's Court in Hammersmith on 19 August 2016 received widespread coverage in the
media, in the main because the cause of the fire was due to a faulty appliance that was subject to a
product recall, an issue which the London Fire Brigade has been campaigning on. However, I am also
drawing this fire to your attention to highlight the external spread of the fire that occurred.

My predecessor, Assistant Commissioner Steve Turek, wrote to housing providers in March 2009 about
a variety of matters relating to fire safety in residential housing blocks. One of those matters was
replacement double glazing and the associated replacement of spandrel and filler panels on the external
faces of blocks of flats with floors above 18 meters in height. In the case of this fire, we believe such
panels were a contributory factor to the external fire spread.

The London Fire Brigade have seen a number of cases where it appears, on the basis of the information
available to us, that the level of fire protection to the external face of the building did not comply with
the requirements of Part B of the Building Regulations insofar as they seek to limit the speed with which
a fire can travel and spread over the external face of a building or may contribute to a fire.

Testing of panels has found that the combustibility of the composition of the panels at Shepherd's Court
did not meet the levels expected for conformity with the building regulations. On testing it was found
that panels may deform or delaminate exposing any combustible core or constituent material resulting in
the panel becoming involved in the fire and allowing the fire to spread and enter flats other than the
flat of origin of the fire.

In many instances, how these panels came to be used is not clear due to the length of time since
installation. However, we have noted that the glazing used in such replacements has usually been
subject to certification under a Competent Persons Scheme for building regulations compliance. It may
have been assumed that the spandrel and in-fill panes were also covered by the certification . Our
understanding is that these Competent Person Schemes in fact only cover glazing, roof lights and doors
containing more than 50 per cent glazing. It is of note that guidance to support some Competent Person
Schemes does not mention the need to ensure compliance with section B4 (External Fire Spread) of the
Building Regulations and instead focused solely on use of windows as means of escape in case of fire.

In the light of fires that have occurred, I would urge you to consider carefully your arrangements for
specifying, monitoring and approving all aspects of future replacement and improvement to building
facades and construction of new buildings for which you are responsible. Contracts for the provision
and installation of replacement elements of building facades, including insulation, replacement double

TBUK5001