Fwd: Your query

Danielle Gregory <[email protected]>
Wed 28/06/2017 11:36
To: [email protected] <[email protected]>;

Two copies if possible

Sent from my iPhone

Begin forwarded message:

From: <[email protected]>
Date: 27 June 2017 at 14:00:55 BST
To: <[email protected]>
Subject: Your query

-----Original Message-----
From: Danielle Gregory [mailto:[email protected]]
Sent: 27 June 2017 11:27
To: [email protected]
Subject: Compartmentation

Dear Sir or Madam

My landlord has asked me to find out if these large cracks along my apartment ceiling and walls would
affect the compartmentation/ stay put policy in my building?

Kind regards
Danielle Gregory

Hi Danielle,

It is very difficult to answer this without further information about the building and your apartment. i.e.
purpose built flat, house altered into flats etc.

However, the openings as they appear on the photographs will allow the products of combustion, smoke,
fire and gases to enter through the walls and ceilings and access other areas of the building. This may
allow fire spread if the fissures that you have photographed are actually “holes” in the compartmentation.
In some areas these parts of the walls and ceilings will have joists and other timber beneath them that will
stop combustion products entering any other area but it could still cause fire spread in the event of an
incident.

It is my opinion these areas should be sealed effectively with an appropriate fire resistant product to
provide effective separation to the building.

A stay put evacuation policy is only applicable in purpose built blocks of flats with a compartmentation
level of 60 minutes for walls and ceilings, it is not a viable option for premises that do not have this level
of separation values. Buildings such as houses converted to flats will have 30 minutes fire resistant
compartments and an evacuation procedure based on the detection and warning system standard would be
applicable in these cases.

End of document