TBUK15009

National Tower Blocks Network, Fire Safety Information Pack

ARCHIVE DOCUMENT
Not stated
1990

A NATIONAL SURVEY OF FIRE SAFETY

A survey of fire safety in tower blocks
across Britain by the National Tower
Blocks Network highlighted the appalling
state of fire safety in many of our tower
blocks. Structural defects, shoddy main-
tenance and cuts in fire-testing have put
many of Britain’s tower blocks in breach
of regulations and below the standards of
bed and breakfast accommodation. In
the seven tower blocks surveyed and in
reports from over 30 tenants associations
a similar picture emerges of the lack of
fire safety in our tower blocks.

GAS LEAKS AND BROKEN
DOORS
Sporle Court, in the London Borough of
Wandsworth, has a piped gas supply. In
the event of a leak the gas had no way to
escape except into the corridor. Kedge
House, in the London Borough of Tower
Hamlets, is of large panel construction,
and the structure is known to be prone to
gaps. BSCP CP3: Chap IV (1962) re-
quires each tower block flat to be able to
withstand a fire for an hour, before
spreading to other flats, thereby allowing
the fire to be extinguished. The gaps
between flats deny tenants this one hour
separation.

INADEQUATE MEANS OF
ESCAPE
In all seven blocks surveyed the means of
escape in the case of fire are inadequate.
A number of fire doors, glazed panels and
rubbish chute covers are broken.
Knighthead Point, in the London Borough
of Tower Hamlets, has had some of the
fire doors missing for four years. In two
blocks in Sheffield, the material used to
line the ceilings of the escape stairwells
are flammable. In a recent move the
London Fire and Civil Defence Authority
have ordered all Fire Services in London
to carry out checks on the surface finishes
in all the tower blocks in their area.

WHAT TO DO NEXT?
The National Tower Block Network is
continuing to campaign on the issue of
fire safety. Let us know about the stand-
ard of fire safety in your blocks. Carry out
your own spot check using the question-
naire in this pack. Contact your local fire
service to ask what checks they carry out.
Ask your local housing department about
maintenance of fire fighting equipment in
your blocks. Then let the National Tower
Blocks Network know because all the
information will be used to back up the
demands for our recommendations to
become law.

STOP PRESS
TENANTS WIN CAMPAIGN TO BE REHOUSED
Tenants in Kedge House, in Tower Hamlets, have successfully campaigned to
be rehoused due to the lack of fire safety in their block. The spot safety check
on Kedge House by the National Tower Blocks Network highlighted the danger
to tenants from fire. This survey has proved to be valuable information in the
tenants' campaign.