Hansard Written Answers

strengthen existing buildings; and measures to be taken
into account in designing new buildings. In addition, there
were interim recommendations about gas disconnection.
4. Following these recommendations the then Ministry
of Housing and Local Government issued advice to local
authorities in circulars 62/68 and 71/68.
5. The advice to authorities was to appraise all their
blocks over six storeys in height which were built of large
pre-cast concrete panels to form load-bearing walls or
floors or both in order to consider whether they were
susceptible to progressive collapse. In considering
whether strengthening was necessary — either by
providing alternative paths of support to carry the load,
assuming the removal of a critical section of the load-
bearing walls or by producing a form of construction of
such stiffness and continuity so as to ensure the stability
of the building against forces liable to damage the load
supporting members—they were to provide for forces
equivalent to a standard static pressure of 5 lb per square
inch (psi) where town gas was to be used. Where it was
not to be used, the forces could be halved, that is, to an
equivalent of 2.5 psi of standard static pressure.
6. As far as can be ascertained, the Ministry did not ask
authorities to inform it of the appraisals or specific action
taken in respect of each block. It is known, however, that
in many cases buildings existing at the time or under
construction were strengthened only to resist forces of 2.5
psi and gas was not reconnected. Ronan Point and five
similar blocks existing or under construction at the time
of the explosion in 1968 were strengthened to resist
pressures of 2.5 psi by the addition of mechanical
connections to the joints between the flank walls and floor
panels; and a structural screed was added to the floor slabs
adjacent to the flank walls.
7. The report of the inquiry (paragraph 173) warned in
specific terms about the dangers of storing explosive
substances such as liquefied petroleum gas (LPG) in such
blocks as this warning was repeated in more general terms
in paragraph 13 of circular 62/68.
Events in 1984
8. Following observation of small gaps at the junctions
between non-load-bearing cladding panels of the facade
and the floor panels in Ronan Point, the London borough
of Newham decided earlier this year to evacuate the block
and in March it appointed Building Design Partnership
(BDP) to investigate this problem and to report on any
defects and incipient or actual fabric deterioration. In April
the brief was extended to include investigations of the
structure of Ronan Point in its current condition with
reference to structural stability, including resistance to
wind, gas explosion and the effects of fire. Subsequently
the council appointed a second firm of consultants,
Thomas Akroyd, and retained the Building Research
Establishment (BRE) to carry out dynamic tests and fire
tests.
9. In July, wide publicity was given to the results of
a fire test in an empty flat by the BRE. The purpose of the
fire was to test the effectiveness of a fire-stop detail
designed by BRE to fill the gaps between the cladding and
the floors described in paragraph 6 and to prevent the
spread of flame and fumes from a flat subject to a fire to
the flat above. Limits were set on the permitted movement
of ceiling panels to prevent unnecessary structural damage
to the flat in which the test was arranged and as a safeguard
for those observing the test. These limits were reached
after about 10 minutes—the fire was deliberately very
severe—and the test was stopped although the severity
of the fire was beginning to decline and it is unlikely that
further structural deformation would have occurred. The
detail proved generally satisfactory although a small
quantity of fumes penetrated the upper flat.
10. Nevertheless considerable local concern was
generated by reports of the fire test and Newham council
arranged for the results to be presented to a public meeting
on 4 August which was attended by a representative of the
Department as well as by the head of BRE’s fire research
station. Subsequently Newham’s housing committee
decided to continue the programme of tests, which was not
complete, and, in response to demands that tenants of the
other eight Taylor-Woodrow-Anglian blocks in the
vicinity of Ronan Point should be rehoused, decided that
priority should continue to be given to rehousing elderly
and disabled tenants.
11. Investigation by the consultants continued and at
the end of September both BDP and Thomas Akroyd
submitted reports to the council, copies of which have
been made available to the Department. These reports
consider the findings of the investigations to date. In
particular, they have found voids in the dry-pack mortar
and in situ concrete in some of the H.2 joints between the
load-bearing flank walls and the floor panels. They
examined the question of the likely behaviour of those
joints in the context of the effects of wind, fire and
explosion.
12. Both BDP and Thomas Akroyd consider that
Ronan Point is not likely to be adversely affected by
anticipated wind pressures, for example, gales such as
could occur once in 100 years, but could seriously be
damaged by an explosion, for example, arising from the
storage or use of LPG cylinders. There is no piped gas
supply in Ronan Point and the five similar blocks. They
also agree that there is a need for an effective fire-stop
detail. BDP considers that in the event of a very severe fire
in two adjoining rooms, the strengthened H.2 joint would
be subject to "stress levels not previously experienced and
therefore unproven". Thomas Akroyd concluded that the
fire resistance of the various parts of the structure is in
accordance with the structural fire resistance required for
such concrete buildings.
13. The BRE is evaluating these reports and discussing
them with the consultants as a matter of urgency. Its
provisional view is that the risk that progressive collapse
of the building—as opposed to localised failure—could
be caused by fire is remote. Nevertheless, it considers that
it is necessary to investigate more fully what, if any,
measures are necessary if buildings of this type are to
remain in satisfactory structural condition in the longer
term.
14. The London borough of Newham, shortly after
receiving the consultants' reports, decided to rehouse
tenants from the five Taylor-Woodrow-Anglian blocks in
Canning town of the same design as Ronan Point and three
Taylor-Woodrow-Anglian blocks of the more recent
revised design, over an expected period of about a year
pending decisions about the long term future of the blocks
and meanwhile to continue the programme of investiga-
tions and tests.
Advice to Owners and Government Action
15. Although difficult technical issues are involved, I
am concerned that the extent of partially-informed
comment on these events in recent weeks may be causing
some local authorities and their tenants undue anxieties.